Skip to main content Skip to search Skip to navigation
Show details
biosignalsplux Researcher 8-Channel Kit for 8 sensors

biosignalsplux Researcher 8-Channel Kit for 8 sensors

Item No.: 1674
€ 5.099,00 € 5.604,00
per pcs
incl. 19% VAT no shipping costs
Net: € 4.284,87
Available immediately
Delivery in: 1 - 2 business days (DE - int. shipments may differ)

Compact wireless biosignalsplux explorer base unit for 8 parallel sensors (sensors OPTIONAL selectable). For body signal analysis for EMG, EEG, EDA, ACC, PZT, FSR, TMP, LUX, ECG, EGG, EOG signals and many more sensors. Included software (via download): OpenSignals (Desktop) + OpenSignals (Mobile). Included software add-ons for OpenSignals (desktop): Video synchronisation. This product is intended for research and development applications only and is not approved for medical use. The sensors can be optionally configured in the shopping basket (see list of sensors below).

More product details
Usage Notice:
Not a medical device. Designed for sports, research, and education. Not intended for the diagnosis, treatment, or prevention of diseases. If you have health concerns, please consult a physician.

Product Information

Item information Value
EAN: 641945959666
HAN: 820201002
Product Type: Set
Applications: BiofeedbackResearchPeak Performance
Target Groups: Research and DevelopmentSchool-Education-Universities-TeachingProfessionalTherapistDevelopers
Product features: EMG SensorMultichannel sensorGSR/EDA SensorEEG SensorECG Sensor
Bundle: Yes
gender: Unisex
age_group: adult
color: white
size: onesize

Product Description

8-channel base unit – sensors available separately

biosignalsplux Researcher Base Unit for 8 Sensors – no sensors included

This 8-channel toolkit is designed to keep advanced research applications within budget while enabling wireless, high-quality signal acquisition. The base unit supports up to 8 sensors in parallel (sensors sold separately).

The included video synchronisation add-on supports video recording during signal acquisition so that captured signals can be visualised synchronously with video for subsequent analysis (e.g. motion analysis).

8 analog sensor ports Up to 3000 Hz 16-bit / channel Video synchronisation Mobile use

MindTecStore: carry case included

A carry case for transport and storage is included in the MindTecStore scope of delivery. Sensors are not included and are ordered separately.

Key features

8 channels for flexible research setups

The Researcher base unit supports parallel acquisition from up to 8 sensors and is suitable for combined biosignal setups in research, development and education.

Wireless streaming

Data transmission is wireless (Bluetooth). Runtime depends on configuration, sensors and usage.

Video synchronisation (add-on included)

The video synchronisation add-on supports recording video during acquisition to align signals with video for review and post-analysis (e.g. motion analysis).

Suitable for dynamic conditions

Thanks to its compact design, the system can also be used for mobile measurements and acquisition under movement (depending on the setup).

Note: Sensors are not included and are available separately.

Optional sensors (selection) – available separately

  • Article number 1661 – Electromyography (EMG)
  • Article number 1664 – Electroencephalography (EEG)
  • Article number 1662 – Electrodermal Activity (EDA)
  • Article number 1665 – Accelerometer (ACC)
  • Article number 1668 – Respiration (PZT)
  • Article number 1669 – Force (FSR)
  • Article number 1667 – Temperature (TMP)
  • Article number 1670 – Light (LUX)
  • Article number 1663 – Electrocardiogram (ECG)
  • Article number 10452 – Electrocardiogram (ECG) LONG
  • Article number 10454 – Electrogastrography (EGG) sensor
  • Article number 10456 – Electrooculography (EOG) sensor

Additional sensors are available on request.

Comparison table – biosignalsplux systems

Feature Solo (1-Channel) Explorer (4-Channel) Researcher (8-Channel) Professional (8-Channel) Hybrid-8 (8-Channel)
Sensor Ports 1× analog + integrated accelerometer & magnetometer 4× analog 8× analog 8× analog 8× hybrid (analog & digital)
Sensor Compatibility biosignalsplux sensors biosignalsplux sensors biosignalsplux sensors biosignalsplux sensors biosignalsplux + digital sensors (e.g. fNIRS, SpO₂)
Max. Sampling Rate up to 3000 Hz up to 3000 Hz (4000 Hz with ≤ 3 channels) up to 3000 Hz (4000 Hz with ≤ 3 channels) up to 3000 Hz (4000 Hz with ≤ 3 channels) up to 3000 Hz (analog), digital depending on sensor
Resolution 16-bit 16-bit 16-bit 16-bit 16-bit (analog), up to 24-bit (digital)
Internal Storage No 16 GB built-in, not unlocked (available as an add-on) 16 GB built-in, not unlocked (available as an add-on) 16 GB built-in & unlocked 32 GB built-in & unlocked
Data Logging No Only with Logging Add-On Only with Logging Add-On Yes (fully functional) Yes (fully functional)
Software Add-ons Available optionally Available optionally Video synchronization included All add-ons included All add-ons included
Included Software OpenSignals Desktop + Mobile OpenSignals Desktop + Mobile OpenSignals Desktop + Mobile OpenSignals Desktop + Mobile OpenSignals Desktop + Mobile
Accessories Bluetooth dongle, Micro-USB cable, 50 electrodes Charger, Bluetooth dongle, 50 electrodes, ground cable, case Same as Explorer Explorer + USB data cable + Sync Kit Same as Professional
Mobile App Yes Yes Yes Yes Yes
Synchronization No Yes (via software) Yes (via software) Yes (Sync Kit included) Yes (Sync Kit included)
Target Audience Basic single-channel use, mobile applications Entry-level research, education Research with video synchronization Comprehensive research with analysis needs High-end research with hybrid sensors

Scope of delivery Researcher 8-Channel Kit (no sensors included)

  • 1 × Wireless 8-channel hub (MTS#10986)
    • 1 × Bluetooth dongle
    • 1 × Medical-grade charger
    • 50 × Electrodes
    • 1 × Portable & robust storage bag
    • 1 x Ground Cable
    • 1 x with EU or US/Japan/China or UK adapter
  • 1 × Carry case (transport & storage) – included by MindTecStore (MTS#10987)
  • 1 × Sensor Synchronization Kit (SYNC) (MTS#1671)
  • Download: OpenSignals (Desktop) + OpenSignals (Mobile)
  • Download: OpenSignals add-on (Desktop): Video Synchronisation (MTS#3130)
Important note: No sensors are included in this base unit. Sensors are available separately.

Software

  • OpenSignals (r)evolution (Windows, macOS, Linux)
  • OpenSignals Mobile (Android)
  • Video synchronisation (add-on)
  • Application programming interfaces (APIs) & sample code on GitHub

Technical data

Analogue connections 8 generic inputs
Auxiliary connections 1 × ground & 1 × digital I/O
Resolution up to 16-bit (per channel)
Sampling rate up to 3 kHz (per channel)
Internal memory Not included (16 GB optionally available)
Battery life ~10 h streaming; ~24 h logging (depending on use and configuration)
Communication Bluetooth Class II
Range up to ~10 m (extendable; environment dependent)
Size 85 × 54 × 10 mm
Weight 45 g (without sensors)
Colour White

Application note

This product is intended for research and development applications only and is not authorised for medical use.

FAQ – frequently asked questions

Are sensors included?
No. Sensors are not included and are available separately.
How many sensors can be used simultaneously?
Up to 8 sensors can be connected and recorded in parallel (depending on the setup and settings).
Is the video synchronisation add-on included?
Yes. The video synchronisation add-on is included for the Researcher version (Desktop).
Is internal storage included?
No. Internal storage is not included. A 16 GB internal memory option is available as an add-on.
Does the system support wireless streaming?
Yes. Wireless data transmission is supported via Bluetooth (range depends on the environment).
Which software is included?
OpenSignals (Desktop) and OpenSignals (Mobile) are included, plus the Desktop add-on video synchronisation.
Is a carry case included?
Yes. MindTecStore supplies a carry case for transport and storage.
What sampling rate and resolution are supported?
Up to 3000 Hz sampling rate and up to 16-bit resolution per channel (configuration dependent).
What is the intended use?
For research, development and education, including prototyping. Not authorised for medical use.
How are sensors ordered?
Sensors are selected and ordered separately using the corresponding item numbers.
Reviews
Write the first review for this item and help others make a purchase decision!
Manufacturer according to GPSR
Plux, Av. 5 de Outubro, 70 - 8º Lisbon Office, 1050-059 Lisboa, Portugal, sales@pluxbiosignals.com, https://www.titan-commerce.com

Responsible person according to GPSR
Plux Wireless Biosignals, Av. 5 de Outubro, 70 - 8º 70-80, 1050-059 Lisboa, Portugal, sales@pluxbiosignals.com, https://www.titan-commerce.com
I am already a customer.
Login for registered customers
Log in

Add product directly to the cart:

You can search by item no. or EAN/GTIN to quickly add the product to the cart.




Service & Hilfe
Service & Hilfe
Customer Service & Support

We’re here to help and support you with all your questions.

Kontakt
  Gottlieb-Daimler-Str. 13, 35440 Linden, Germany
  Tel: +49 6403-60993-51
  (Mon-Fr.) 9:00 - 17:00

or copy this link